Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use; Technical Data - Würth Acctivia Expert 12/24 V 35 A Original Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Intended use

The charger is intended solely for the charging of
vehicle batteries (referred to throughout the docu-
ment as "battery(ies)".
Any other use or use beyond this scope is consid-
ered improper use.
The manufacturer accepts no responsibility for dam-
ages resulting from such use.
The user is responsible for damage result-
ing from improper use.
Device elements [Fig. I]
Information
As a result of firmware updates, your
device may have functions available
that are not described in these operating
instructions or vice versa. Moreover,
individual figures may differ slightly in
respect of the control elements of your
device. Nevertheless, the functioning of
these control elements is identical.
Operating panel overview
1 25% charging state indication
2 50% charging state indication
3 75% charging state indication
4 100% charging state indication
5 Ready for operation indication, 12 V charging
voltage
6 Ready for operation indication, 24 V charging
voltage
7 Start/Stop, voltage selection and setup button
8 Fault indication
Overview of reverse side of housing
9 Mains supply socket
10 Mains cable retaining clip
11 Connection P1 - charging cable socket
14

Technical data

Input electrical data
Mains voltage
Frequency
Mains current
Mains fuse
Efficiency
Active power
Power consumption
(standby)
Protection class
EMC emission class
Output electrical data
Nominal output voltage
Output voltage range
Output current
Battery reverse current
Mechanical data
Cooling
Dimensions L x W x H
(in mm)
Weight (without cable)
Environmental Conditions
Operating temperature
Storage temperature
Energy efficiency class
Degree of protection, hori-
zontal orientation
Degree of protection, verti-
cal orientation
230 V AC
50 / 60 Hz
max. 7.7 A eff.
max. 16 A
max. 96%.
max. 1120 W
max. 1.7 W
I (with protective
conductor)
A
12 V / 24 V DC
2 V - 33.6 V DC
35 A at 14.4 V DC
35 A at 28.8 V DC
< 1 mA
Convection and fan
270 x 168 x 100
2.4 kg
-20 °C - +40 °C
(>30 °C derating)
-40 °C - +85 °C
B
IP40
IP44