Herunterladen Inhalt Inhalt Diese Seite drucken

Tool Specifications; Intended Use - Würth AL 60-AS-LI Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
OBJ_BUCH-0000000088-003.book Page 8 Tuesday, July 28, 2015 3:14 PM

Tool Specifications

Battery charger
Article number
Voltage range
Charging current, rapid charging
Trickle-charging current
Charge duration with 2.0 Ah
Charge duration with 3.0 Ah
Charge duration with 4.0 Ah
Weight without power cord
Battery
Article number
Voltage
Rated capacity
Number of cells
Type of cell for battery
Battery
Article number
Voltage
Rated capacity
Number of cells
Type of cell for battery
Battery
Article number
Voltage
Rated capacity
Number of cells
Type of cell for battery

Intended Use

The battery charger is suitable for automatic charging
and re-charging of Würth battery LI-AS 18 V/2.0 Ah,
LI-AS 18 V/3.0 Ah, LI-AS 18 V/4.0 Ah.
For damage caused by usage other than intended, the
user is responsible.
AL 60-AS-LI
0700 813
18 V
3.0 A
500 mA
40 min
60 min
80 min
260 g
BTRYPCK-
LIION-AS-
18V/2.00 Ah
0700 913 733
18 V
≤ 2.0 Ah
1 x 5
Li-Ion
AKKU-LI-AS
18 V/3.0 Ah
The battery is supplied partially charged. The LEDs on
0700 913 731
the battery indicate the charge condition.
18 V
When the battery is not used for longer periods, it
≤ 3.0 Ah
switches to the idle state.
2 x 5
Pay attention that the charger contacts are protected
Li-Ion
against debris and moisture, and are not obstructed
AKKU-LI-AS
through foreign objects. Do not operate the charger in
18 V/4.0 Ah
extreme hot or cold locations. It operates best at nor-
mal room temperature.
0700 913 732
The battery is automatically charged after inserting it to
18 V
the charger contacts (red LED lit).
≤ 4.0 Ah
When a too warm or too cold battery is inserted into
2 x 5
the charger (red LED flashes), the charging procedure
Li-Ion
will start as soon as the battery has reached the correct
temperature range (-10 ... + 66°C) again and the
max. charging current can flow.
When the battery is completely charged, the LED indi-
cator switches from red to green and the LED indicator
on the battery goes out.
After charging, the battery does not have to be
removed from the charger immediately. The battery
can remain in the charger. It cannot be overcharged
and is thus always ready for operation.
Symbols
Read all safety warning and opertor's
manual
Warning
This tool is only suitable for indoor use.
Never expose tool to rain.
Class II equipment
Time-lag fuse 3.15 A
CE Conformity mark
Operating Instructions
8

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

0700 813

Inhaltsverzeichnis