Closing the device
④⑦
1. Screw the covers
2. Secure each cover with the cover catch
3. Close the key cover
4. Tighten the screws in the key cover.
5. Check the tightness of the blanking plugs
Key cover
Cable gland
Safety catch (back)
Cover (rear) for electrical terminal compartment
Figure 6
View of the transmitter: Left: Back right: Front view
Commissioning
Basic safety instructions
DANGER
Toxic gases and liquids
Danger of poisoning when the device is vented.
If toxic process media are measured, toxic gases and liquids can be released when the device is vented.
● Before venting ensure that there are no toxic gases and liquids in the device. Take the appropriate safety measures.
WARNING
Improper commissioning in hazardous areas
Device failure or danger of explosion in hazardous areas.
● Do not commission the device until it has been mounted completely and connected in accordance with the information
in Chapter "Technical specifications (Page 35)".
● Before commissioning take the effect on other devices in the system into account.
SITRANS P, DS III series (7MF4.33.. 7MF4.34.. 7MF4.35..)
A5E03434626-01, 08/2011
back on as far as they will go.
③⑥
.
.
and cable gland
in accordance with the degree of protection.
8
Blanking plug
Safety catch (front)
Cover (front), optionally with inspection window
Safety catch for stainless steel enclosure
23