O
algorithm are saved in the permanent memory of the device.
Locking/unlocking the device buttons
A
B
Counting operating hours
C
TA350
TA350
TA350
Press button P O to confirm the minimum
ON time and switch to adjusting the pro-
portional band.
Use the
buttons to adjust the value of
the proportional band to between 1 and 3 °C.
Press button P to exit programming.
N.B. All parameters related to the configura-
tion of the type of temperature management
To protect the device from changes to the
set programming, press buttons P and
A at the same time for at least 3 seconds.
Use the
buttons to lock/unlock the
buttons B.
+
= Lock active
= Lock not active
With the lock on, the only active button is
, which can be used to show the current
time and temperature detected.
The user is free to select one of the three
pre-programmed levels without having the
option to change them.
Press button C.
The display shows the operating time for
5 seconds C.
To reset the counter, press the button
while the figure is visible.