Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Diagram - Daikin Siesta R410A SERIES Installationsanleitung

Vorschau ausblenden Andere Handbücher für Siesta R410A SERIES:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 39
Indoor Unit
50mm or more from walls
(on both sides)
INSTALLATION OF THE OUTDOOR UNIT (ARXN25/35MV1B)
Where a wall or other obstacle is in the path of outdoor unit's intake or exhaust airflow, follow the installation guidelines
below.
For any of the below installation patterns, the wall height on the exhaust side should be 1200mm or less.
Wall facing one side
More than 50
Side View

INSTALLATION DIAGRAM

30mm or more from ceiling
Front panel
M4 x 12L
Air filter
Outdoor Unit
More than 100
1200 or
less
Caulk pipe
hole gap
with putty.
Service lid
ó
Opening service lid
Service lid is opening/
closing type.
ó
Opening method
1) Remove the service lid
screws.
2) Pull out the service lid
diagonally down in the
direction of the arrow.
3) Pull down.
Wall facing two sides
More than 50
Wall facing three sides
More than 50
Top View
1-6
Cut thermal insulation pipe to an
appropriate length and wrap it with
tape, making sure that no gap is left
in the insulation pipe's cut line.
Wrap the insulation pipe
with the finishing tape
from bottom to top.
More than 150
More
than 100
Top View
More than 150
More than 300
More than 50
Unit : mm

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis