Herunterladen Inhalt Inhalt Diese Seite drucken

Dometic DC-Kit5 Montage- Und Bedienungsanleitung Seite 23

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
DC-Kit5
• B2200, B1600 Plus, FJ1100, FJ1700, FJ2200, FL1600, FL2200,
FW3000
If the charging voltage regulator cuts the connection to the supply battery due
to low voltage, it switches off the roof air conditioner at the same time. The
inverter remains active and has voltage in its socket.
As soon as the voltage in supply battery has reached the switch-on point in the
charging current distributor, the roof air conditioner switches on again.
If the voltage in the supply battery drops further and goes below the 21 V switch-
off point for the inverter, the inverter switches off (chapter "Driving mode: power
supply from the 24 V battery with motor switched off" on page 22).
• B1600, HB2500
If the charging voltage regulator cuts the connection to the supply battery due
to low voltage, it switches off the inverter at the same time using the MCR-9
remote control. There is no voltage in the socket for the inverter.
As soon as the voltage in the supply battery reaches the switch-on point in the
charging current distributor, it restores the connection between the starter and
supply battery and switches the inverter on again using the MCR-9 remote
control. There is voltage in the socket again for the inverter.
The air conditioning starts again automatically.
If the voltage in the supply battery drops further and goes below the 21 V switch-
off point for the inverter, the inverter switches off (chapter "Driving mode: power
supply from the 24 V battery with motor switched off" on page 22).
8.2
Switching off the system
➤ First of all, switch off the air conditioning.
➤ If there are no more consumer units which need power, switch off the inverter
using the MCR-9 remote control.
EN
Using the DC kit
23

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis