Herunterladen Inhalt Inhalt Diese Seite drucken

Dometic DC-Kit3 Montage- Und Bedienungsanleitung Seite 19

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
DC-Kit3
➤ Connect the universal connection cable with connections I2 and I5 of the
charging current distributor ( ECL-102) (fig. 3 1 and 2, page 4).
➤ Run the connection cable of remote control MCR9 to the inverter and connect
( MSI1812T).
7.9
Connecting the B1600 and HB2500 Dometic roof air
conditioner
➤ Connect the D+-output on the light system using a 1,5 mm² cable to connection
I2 of the changing current distributor ( ECL-102) (fig. 3 1, page 4).
➤ Connect the I5-output of the ECL-102 to the control cable connection on the
MCR9 remote control (fig. c 1, page 8).
7.10
Connecting the DC kit to the power supply
➤ Check that all the connections have been made in accordance with the
instructions.
➤ Check that the roof air conditioner is closed properly.
➤ Connect the electrical connections of the components ( ECL-102).
➤ Connect the 230 V connection on the roof air conditioner with the MSI1812T
inverter plug ( MSI1812T).
➤ Connect the positive battery cables to the batteries.
➤ Check the following are working properly:
– Check the on and off values for the charging voltage regulator
– Check the priority circuit
– Switch on the air conditioning in driving mode ( air conditioning)
– Switch on the air conditioning on mains operation
➤ Only CA1000: adapt the roof air conditioner software to AC/DC operation
( CA1000).
EN
Installing and connecting the DC kit
19

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis