3.4.2. Regeneration time setting
The following window will appear while accessing this parameter by means of key SET „■":
To scroll within the window use the same procedure as under item „3.4.1.".
3.4.3. Regeneration cycle setting
The following window will appear while accessing this parameter by means of key SET „■":
This parameter is set in the factory for 7 days for Timer mode and for 10 days for Mix mode. It is
recommended to maintain these settings.
You will find hereinafter in this handbook the procedure to select the regeneration mode. If you select the
Timer mode it would be appropriate to set this parameter at the value of 3 days.
In order to scroll within the window you should use the same procedure as under item „3.4.1.".
3.4.4. Regeneration meter capacity settings
The following window will appear when accessing this parameter by means of key SET „■":
This parameter is set at 6 m
!
This parameter is very important for the correct operation of the station and will be introduced by
the beneficiary, differing from one situation to another one.
In order to correctly calculate this parameter you need to know the water hardness and the cyclic
capacity of the station you procured.
As such : The cyclic capacity for each station is found at the beginning of this handbook under chapter
"1. Models and technical characteristics".
Hardness is stated in the test bulletin for the water that is to be treated. (for test performance please
contact the company Valrom Industrie).
Calculation formula:
Regeneration Meter Setting between 2 regenerations = Cyclic capacity / Hardness = [m³]
Calculation example:
Cyclic capacity = 75 for "Softening station <aquaPUR> SOFT 25" (according to chapter "1. Models and
32
꞊꞊꞊꞊꞊Regen. Time꞊꞊꞊꞊꞊
00:00
Press
Press ■ to Confirm
꞊꞊꞊꞊꞊Regen. Cycle꞊꞊꞊꞊꞊
00 days
Press
to Return
Press ■ to Confirm
꞊꞊꞊꞊꞊Regen. Meter Setting꞊꞊꞊꞊꞊
Capacity: 00.00 m
Press
to Return
Press ■ to Confirm
in the factory.