1 • INSTALLATION
• Dimensions and cut-out; panel mounting
108
96
48
44,5
157
10
Panel mounting:
To fix the unit, insert the brackets provided into the seats on either side of the
case. To mount two or more units side by side, respect the cut-out dimensions
shown in the drawing.
3 • TERMINALS
max.6,9
With fork terminal;
with tinned wire;
with ring terminal
2308
MULTIZONE INDICATOR / ALARM UNIT
115
92
For correct and safe
installation, follow
the instructions and
observe the
warnings contained
in this manual.
Low-signal line
max.6,9
USER'S MANUAL
SOFTWARE VERSION 4.x
code 80330 / Edition 0.6 - 04/02
ISO 9001
2 • TECHNICAL SPECIFICATIONS
Resolution
Accuracy
Acquisition speed
Thermocouples
Resistance Thermometer
Power supply
Relay output
Logic output
70
Protections
Work temperature
Function
CE MARKING: EMC conformity (electromagnetic compatibility) with EEC Directive
89/336/CEE with reference to the generic Standard EN50082-2 (immunity in industrial
!
environments) and EN50081-1 (emission in residential environments). BT (low voltage)
conformity respecting the Directive 73/23/CEE modified by the Directive 93/68.
MAINTENANCE: Repairs must be done only by trained and specialized personnel. Cut
power to the device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene, etc.).
Use of these solvents can reduce the mechanical reliability of the device. Use a cloth
dampened in ethyl alcohol or water to clean the external plastic case.
SERVICE: GEFRAN has a service department. The warranty excludes defects caused
by any use not conforming to these instructions
EMC conformity has been tested with the following connections
FUNCTION
Power supply cable
Relay output cable
Digital communication wires
TC input
Pt100 input
4 • SUGGESTED CONNECTIONS
A
+
22
21
20
19
18
17
16
15
14
13
1
2
3
4
5
6
7
8
9
10
B
C
10
GEFRAN spa via Sebina, 74
25050 Provaglio d'Iseo (BS) ITALIA
Tel. 0309888.1 - Fax 0309839063
Internet: http://www.gefran.com
4000 pt
0.1% fs TC - RTD - dc inputs
0.5% fs ac inputs - RTD (-99.9... 100.0°C)
160msec per channel
J, K, S, R, T
RTD Pt100 2-wires
RTD Pt100 3-wires
90...260 Vac/dc, 48...62 Hz absorbed power 4W
(10...30Vac/dc on request)
NC/NO selectable with jumpers
(5A/220Vac cosϕ = 1) (1,5A cosϕ = 0,2)
25V/15mA max
- "Watch-dog" protection circuit for instrument
reset in case of interference
- 3 SW protection levels
- jumper to enable access to calibration from panel
keys
0...50°C
8-bit microprocessor
CABLE TYPE
1 mm
2
1 mm
2
0,35 mm
2
0,8 mm
2
compensated
1 mm
2
Feeder and output line
D
A
E
B
C
12
11
D
E
LENGTH
1 m
3,5 m
3,5 m
5 m
3 m
SERIAL
INPUTS
MD81 EXPANSION
OUTPUTS /RELAYS
FEED