FUNCTIONAL DESCRIPTION

CAUTION:
Always be sure that the tool is switched off and the
battery cartridge is removed before adjusting or
checking function on the tool.
Take care not to trap finger(s) between cleaner and
battery as shown in diagram when loading
battery.Trapping finger(s) may cause injury.
Fig.1
Installing or removing battery cartridge
Fig.2
Always switch off the tool before installing or
removing of the battery cartridge.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on
the battery cartridge with the groove in the housing
and slip it into place. Always insert it all the way
until it locks in place with a little click. If you can see
the red indicator on the upper side of the button, it is
not locked completely. Install it fully until the red
indicator cannot be seen. If not, it may accidentally
fall out of the tool, causing injury to you or someone
around you.
Do not use force when installing the battery
cartridge. If the cartridge does not slide in easily, it
is not being inserted correctly.
Battery protection system (Lithium-ion
battery with star marking)
Fig.3
Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically cuts
off power to the tool to extend battery life.
The tool will automatically stop during operation if the tool
and/or battery are placed under one of the following
conditions:
Overloaded:
The tool is operated in a manner that causes
it to draw an abnormally high current.
In this situation, release the trigger switch on
the tool and stop the application that caused
the tool to become overloaded. Then pull the
trigger switch again to restart.
If the tool does not start, the battery is
overheated. In this situation, let the battery
cool before pulling the trigger switch again.
Low battery voltage:
The remaining battery capacity is too low and
the tool will not operate. In this situation,
remove and recharge the battery.
Switch action
Fig.4
CAUTION:
Before inserting the battery cartridge into the tool,
always check to see that the switch trigger actuates
properly and returns to the "OFF" position when
released.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
ASSEMBLY
CAUTION:
Always be sure that the tool is switched off and the
battery cartridge is removed before carrying out
any work on the tool.
Disposing of Dust
CAUTION:
Empty the cleaner before it becomes too full, or the
suction force weakens.
Be sure to empty out the dust inside the cleaner
itself. Failure to do so may cause the filter to be
clogged or the motor to be damaged.
Fig.5
In order to drop dust sticking on the filter in the capsule,
tap the capsule 4 or 5 times with your hand.
Fig.6
Now point suction inlet downwards, turn capsule in
direction of arrow in diagram, and disconnect capsule
slowly and straight.
NOTE:
Dust may spill out when capsule is opened, so be
sure to set a garbage bag beneath capsule.
Fig.7
Remove accumulated dust from inside of capsule and off
of prefilter.
Fig.8
Twist prefilter in direction of arrow to unfasten securing
lip from cleaner unit and then pull off prefilter.
Fig.9
Clean out fine dust from prefilter. Next, remove filter, and
lightly tap to dislodge dust.
Reassembly
Fig.10
Put on filter until it is fully in position on the cleaner unit.
NOTE:
Make sure filter is put on straight without being
peeled back. If filter is put on incorrectly as shown
in diagram, dust will get into motor housing, and
cause motor failure.