3.3A.2. INSTALL THE FILTERS
• Install the fi lters to the unit.
AR07/09/12/14/18: 2 fi lters
AR24: 3 fi lters
3.3A.3. DRILLING HOLES FOR BOLTS AND INSTALLING
THE BOLTS
• Using the installation template, drill holes for bolts (4 holes).
Installation template
AR07/09/12/14
A
734 mm
3.3A.4. FIX THE UNIT
(1) Hang the unit
Hanger bolt
Nut A
(Field supply)
Washer
(Accessories)
Nut B
(Field supply)
En-5
9374342273-01_IM.indb Sec1:5
9374342273-01_IM.indb Sec1:5
Filter (Accessories)
Unit
Filter
Drilling position
for bolts
Air
A
AR18
AR24
934 mm
1134 mm
Hanger
Hanger bolt
Nut A
(Field supply)
Washer
(Accessories)
Nut B
(Field supply)
*: It might become difficult to open and shut the Cover/control box cover when the
length exceeds 20 mm.
(2) Leveling
Base horizontal direction leveling on top of the unit.
Ceiling
Level
Good
Level
Air
Good
CAUTION
Leave a space of 100 mm or more between the inlet port and the ceiling.
Fasten the unit securely with Special nuts A and B.
3.3B. Installation the unit (Wall mounted type/Floor
standing concealed type)
WARNING
Install the air conditioner in a location which can withstand a load do at least 5 times the
weight of the main unit and which will not amplify sound or vibration. If the installation
location is not strong enough, the indoor unit may fall and cause injuries.
If the job is done with the panel frame only, there is a risk that the unit will come loose.
Please take care.
Hanger
Unit
20 mm
length
Cover
Prohibited
Prohibited