before handing any internal components.
You must dismantle and clean the machine at
the end of the day or each time you use a
different product.
Any components in contact with the food
must be cleaned immediately after use, using
hot water and a food-safe detergent. Then
rinse with plenty of hot water and disinfect
using an ethyl alcohol-soaked cloth (90 º). DO
NOT use abrasive detergents (nitric acid, neat
bleach, etc.) or stainless steel scourers or
scrubbers. They could cause rusting.
The removable parts of the machine are not
dishwasher safe. Detergents could damage
the surface.
- If the dirt is dry and stuck to the pot and the
blades pour hot water and detergent into the pot
and switch the machine on to soften the residue.
- To avoid splashes, once the product has been
processed, remove the lid (U), place the
bayonet mechanism (Y) in the open position
(AA) and remove the pot (S) with the blade
inside (T).
- You can remove the mixer (V+X) from the lid
(U). To do so, keep the mixer (X) firmly in place,
tighten and turn the mixer handle (V). Once you
have done this you can separate the mixer and
the mixer handle. To reassemble the mixer,
insert the mixer (X) into the lid (U) again and the
mixer handle (V) into the mixer (X). Push the
mixer (X) and the mixer handle (V) against the
lid and turn the mixer handle (X) until it will no
longer turn. Once you have done this, separate
the mixer (X) and the mixer handle (V).
- Cleaning the motor block:
NEVER power clean. Use a damp cloth and
mild detergent for cleaning. DO NOT use
abrasive detergents (nitric acid, neat bleach,
etc.) or stainless steel scourers or scrubbers as
they could cause rusting.
MAINTENANCE
CAUTION
- Before undertaking any cleaning, inspection or
repair work on the machine, the machine must
be unplugged from the mains.
- Regularly check that the machine safety devices
are working. If you detect any anomaly, call the
SAMMIC authorised technical service.
- Regularly inspect the trailing axle seal to ensure
that this area is properly sealed. Every time you
loosen the trailing axle for maintenance you
should fit a new seal.
- Clean the machine after every use, as described
8
EN
above.
- Only a SAMMIC authorised technical service
can replace the power cable if this is damaged.
- Machine noise level, while running, at a height
of 1.6 m and a distance of 1 m, less than 77
dB(A). Background noise: 32 dB(A).
BLADE SHARPENING
WARNING: The blade set (T) is fitted with very
sharp blades, so they must be handled with
care.
The cutters (T) can be dismantled easily for
sharpening. Always use soft stone to keep the
blade's cutting angle intact.
TROUBLESHOOTING
CK models
When the machine is ready for operation and you
press "On" in slow or fast mode (buttons 7 or 11)
the machine does not start:
- If the "speed" light (12 or 13) blinks there is a
problem with the lid (U). Check the lid (U) is
correctly in place, the system for lowering the
magnet that is in the pot (S) or finally the
detector that is in the lower cover (F).
- Whitout pot if the slow and fast mode lights blink
at the same time (12 and 13) check the bayonet
mechanism (Y) is closed (Z), the magnet
associated with it or finally the detector in the
lower cover (F).
- If the speed (12 or 13) and machine connected
to the mains (14) lights blink, the thermal relay of
the motor has been tripped. The motor is
overloaded or the machine is working in "two-
wire".
The CK-5 and 8 are programmed to stop
automatically if no device is operated within 15
minutes.
Verifying the keypad: To see that the keypad
works, hold down any button for 3 seconds and
the "machine connected to the mains" light (14)
should turn off.
CKE models
The machine is ready for use, but when you press
"On" (7) the machine does not start and SE
(Safety) appears on the display:
- If you hold down "On" (7), it indicates which
sensor has not been detected.
d1: Bayonet mechanism
d2: Cutter Detector If there is only the engine
block.
- Some of the safety devices are disabled. Check
that all of the components are in position.
- The error persists after running the above
check. There is a problem with one of the safety
devices. Call a SAMMIC authorised technical
assistance service.
"E1" on the display means that a variable
frequency drive safety device has been activated.
To exit this status, press disconnect the machine
from the mains and wait.
The display (1) does not light up: There is no
power supply to the display or the electronic
control board is broken.
To verify that the keypad works correctly, with the
cutter/emulsifier attachment fitted, press the keys
and verify that the plate beeps and the display
reacts. If it does not, change the keypad.
The CKE-5 and 8 are programmed to stop
automatically if no device is operated within 30
minutes.
OTHER IMPORTANT INFORMATION
This machine is not designed for use by people
(including children) with reduced physical,
sensory or mental capabilities or lacking the
necessary experience or knowledge, unless they
have received supervision or instructions from a
health and safety expert.
This machine is for supervised use. Never leave
the machine running unsupervised.