Appendix A: EMC Information

G
M
UIDANCE AND
ANUFACTURER
electromagnetic environment specified below. The user of this device should make sure it is used in such an environment.
E
T
MISSIONS
EST
RF emissions
CISPR 11
RF emissions
CISPR 11
Harmonic emissions
IEC 61000-3-2
Voltage fluctuations/Flicker emissions
IEC 61000-3-3
G
M
UIDANCE AND
ANUFACTURER
electromagnetic environment specified below. The user of this device should assure that it is used in such an environment.
I
T
MMUNITY
EST
Electrostatic Discharge (ESD)
IEC 61000-4-2
Electrical Fast Transient/Burst
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips, short
interruptions and voltage
variations on power supply
input lines
IEC 61000-4-11
Power frequency (50/60 Hz)
magnetic field
IEC 61000-4-8
Note: U
is the a.c. mains voltage prior to application of the test level.
T
'
D
- E
S
ECLARATION
LECTROMAGNETIC
C
OMPLIANCE
Group 1
Class B
Class A
Complies
'
D
- E
S
ECLARATION
LECTROMAGNETIC
IEC 60601 T
EST
L
EVEL
±6 kV contact
±6 kV contact
±8 kV air
±8 kV air
±2 kV for power supply lines
±2 kV for Power Supply Lines
±1 kV for input-output lines
NA - Device does not have user
I/O lines that are longer than
3 m in length.
±1 kV Line to Line
±1 kV Line to Line
±2 kV Line to Ground
NA - The device is a Class II
device and does not connect
to earth ground.
<5% U
<5% U
T
(>95% dip in U
) for 0.5 cycle
T
40% U
40% U
T
(60% dip in U
) for 5 cycles
T
70% U
70% U
T
(30% dip in U
) for 25 cycles
T
<5% U
<5% U
T
(>95% dip in U
) for 5 sec
T
3 A/m
3 A/m
E
:
MISSIONS
E
LECTROMAGNETIC
The device uses RF energy only for its internal function. Therefore, its
RF emissions are very low and are not likely to cause any interference
in nearby electronic equipment.
The Device is suitable for use in all establishments, including
domestic establishments and those directly connected to the public
low-voltage power supply network that supplies buildings used for
domestic purposes.
I
:
MMUNITY
C
L
OMPLIANCE
EVEL
Floors should be wood, concrete or ceramic
tile. If floors are covered with synthetic
material, the relative humidity should be at
least 30%.
Mains power quality should be that of a
typical home or hospital environment.
Mains power quality should be that of a
typical home or hospital environment.
Mains power quality should be that of a
T
(>95% dip in U
) for 0.5 cycle
typical home or hospital environment. If
T
the user of the device required continued
T
(60% dip in U
) for 5 cycles
operation during power mains interruptions,
T
it is recommended that the device be
T
(30% dip in U
) for 25 cycles
powered from an uninterruptible power
T
supply or a battery.
T
(>95% dip in U
) for 5 sec
T
Power frequency magnetic fields should be
at levels characteristic of a typical location in
a typical home or hospital environment.
EverFlo / EverFlo Q User Manual
This device is intended for use in the
E
- G
NVIRONMENT
UIDANCE
This device is intended for use in the
E
E
LECTROMAGNETIC
NVIRONMENT
G
UIDANCE
-