7. Frost protection

Using the Frost Protection Mode instead of turn-
ing the thermostat OFF completely may protect
against damages due to low temperatures. The
room temperature will be maintained around 5 °C.
• Turn OFF the thermostat by pressing
• Press M Fig.1
• Select 01 (00= disabled).
If the room temperature is lower than 5 °C the
heating will be turned ON and
in the display.
If the room temperature is higher than 7 °C the
heating is turned OFF.
Factory setting is 00.

8. Error messages

E1 will be displayed when room sensor failure.
E2 will be displayed when floor sensor failure. E2
will be read when pressing M Fig. 1
floor temperature.
Any case, all relay output would be turned off.