  • DEUTSCH, seite 12
because it is less costly than other inert gases, but you may
also use blends of ARGON with a maximum of 2%
HYDROGEN for welding stainless steel, and HELIUM or
ARGON-HELIUM blends for welding copper.
These blends increase the heat of the arc while welding, but
are much more expensive.
If you are using HELIUM gas, increase the litters per minute
to 10 times the diameter of the electrode (Ex. diameter 1.6 x
10= 16 It./min of Helium).
Use D.I.N. 10 protective glasses for up to 75A, and D.I.N. 11
from 75A up.
3.6 SAVING
You may save parameters only after welding.
Pressing the push-button Y briefly makes a selection, while
holding it down for more than 3 seconds saves the data.
Each time it is turned on, the machine always shows the last
welding condition used.
3.6.1. Saving data from the PL program
Using the machine for the first time
When the machine is turned on, the display shows the
symbol PL; this disappears after 5 seconds, and a working
current is displayed. Follow the instructions in paragraphs 3.2
and 3.5, then proceed as follows to save the data in the
program P01:
• Briefly press the push-button Y, the message P01 will
appear flashing.
• Press push-button Y for more than 3 seconds, until the
symbol P01 stops flashing: at this point, the data have been
saved.
• Obviously, if you wish to save in a program other than P01,
you should briefly press the push-button Y as many times as
necessary to display the desired program. P01 will be
displayed the next rime the machine is turned on.
PRESSING THE Y PUSH-BUTTON BRIEFLY MAKES A
SELECTION, WHILE HOLDING IT DOWN FOR MORE
THAN 3 SECONDS SAVES THE DATA.
3.6.2.
Save from a free program
The operator may edit and save a selected program by
proceeding as follows:
• Press the push-button Y briefly and select the desired
program number.
• The symbol of free programs is flashing.
• Press the push buttons C, X and A3 and select the welding
procedure and mode (paragraph 3.2).
• Turn the knob R and set the welding current.
• If the TIG procedure has been selected, activate the LED
A4 (post gas) by means of the push-button G, and set the
desired value via the knob R (paragraph 3.2.)
• If you wish to adjust the "slope" times or other parameters,
after making these adjustments which are necessary in
order to weld, follow the steps described in paragraph 3.2.
• Weld, even briefly, and decide where to save
• To save in the previously selected program, press the
button Y for more than 3 seconds, until the number stops
flashing.
• To save in a different program, make your selection by
briefly pressing the push-button Y, then hold down the push
button Y for more than 3 seconds.
3.6.3
Save from a saved program
Beginning with a previously saved program, the operator may
edit the data in memory to update the program itself, or to
find new parameters to save in another program.
3.6.3.1 Update
• Alter turning on the machine, select the parameters to
be edited and edit them.
• Weld, even briefly.
• Hold down the Y button for more than 3 seconds, until
the save is confirmed (program symbol changes from
flashing to steady).
3.6.3.2 Save in a new program
• After turning on the machine, select the parameters to
be edited and edit them.
• Weld, even briefly.
• Briefly press the selector Y until the desired program is
displayed.
• Hold down the Y button until the save is confirmed
(program symbol changes from flashing to steady).

4 REMOTE CONTROLS

The following remote controls may be connected to this
machine to adjust the welding current:
Item 570007 Foot control (used in TIG welding)
Item 535805 TIG UP/DOWN Torch.
Item 530330+ltem 570006 (used in MMA welding)
Item 363307 Connection to simultaneously connect the
torch and the pedal control. With this accessory, item
570007 may be used in any TIG welding mode.
Remote
controls
regulate the welding current from the minimum to the
maximum current set via the knob R.
Remote controls with UP/DOWN Iogic regulate the
welding current from the minimum to the maximum.
Remote control settings are always active in the PL
program, while they are not active in a saved program.