Safety notes
• Installation is only possible in frost-free rooms.
• The control electronics are only suitable for indoor use.
• Use only original spare parts.
Technical data
• Supply voltage
(transformer 230 V AC/12 V AC)
• Power consumption
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (factory setting):
• Flow volume
• Intermediate flush
• Automatic flush
• Type of protection
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature of ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage
and rated current.
Approval and conformity
This product conforms to the requirements
of the relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Special accessory
• The following settings can be made and changed with the
infrared remote control (Prod. no.: 36 407).
Installation
Plaster and tile the wall, excluding the area of the structural
shell protection.
Final installation
1. Remove screws (A1) and cut off structural shell
protection (A) flush with the wall, see Fig. [1].
2. Open isolating valve (H) and flush pipe for at least 5 s,
see Fig. [2].
3. Close isolating valve again, see Fig. [2].
4. Align frame (B) and fasten using screws (B1), see Fig. [3].
5. Replace spacer (C) with solenoid valve (D), during this
process pay attention to the seals (D1) and the direction
of flow, see Fig. [4].
6. Fit headpart (F) of the transformer to the base (G),
see Fig. [5], remove protection first.
7. Connect headpart (F) of the transformer to the
electronics (E), see Fig. [6].
8. Connect solenoid valve (D) to electronics (E), see Fig. [6].
9. Open isolating valve (H), see Fig. [7].
10. Engage plate (E) at top of frame (I) and snap into position
at bottom by gently pushing, see Fig. [8].
11. Fasten plate (E) using locking screw (E1), see Fig. [8].

Operation

230 V AC
The infrared-electronic system emits invisible,
pulsed light. If this light is reflected by a user for
3.2 VA
approx. 10 s (= minimum delay time) and is then received
again by the electronic system, the solenoid valve is activated
45cm
approx. 1 second after the user moves away. The solenoid
3 l (factory setting)
valve opens and the bowl is flushed.
Adjustable 1 - 7 l
The range of sensitivity is dependent upon the reflective
Every 2 min (max. 14x)
properties of the object.
(factory setting: activated)
24 hours
(factory setting: activated)
IP 55
Making settings
A
2
Setting mode
2500 V
100 °C
The flow volume can be checked and changed in setting mode
(see Setting the flow volume).
The detection zone of the fitting can be checked. The indicator
lamp in the sensor system of the fitting illuminates in setting
mode when the detection zone of the fitting is reached
by an approaching user.
It is possible to set the detection zone via the optional
remote control.
Flushing is immediately triggered when the detection zone
is exited again. The minimum delay time is not available
in setting mode.
To activate setting mode, proceed as follows: Disconnect
the power supply to the electronics and reconnect after 5 s,
see Fig. [10].
Setting mode is activated. Setting mode is automatically
terminated after 3 min.
Setting the flow volume
The factory-set flow volume is approx. 3 litres at a flow
pressure of 3 bar.
The flow volume can be changed as follows:
1. Activate setting mode (see above).
2. Hold hand at a distance of approx. 5 - 10cm in front of the
sensor system in the fitting. The indicator lamp in the sensor
system of the fitting flashes quickly.
3. The indicator lamp extinguishes automatically after
approx. 5 s.
4. Remove hand from the detection zone (at least 60cm).
5. Again hold hand at a distance of approx. 5 - 10cm in front
of the sensor system.
The flow volumes are indicated via the indicator lamp in the
sensor system by groups of flashing signals separated
by a pause.