Baumer TE2 Betriebsanleitung Seite 11

Kompakter rtd-temperatursensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Process temperature as a function of ambient temperature
300
250
200
150
100
50
0
0
20 40 60 80 100
Tamb (°C)
13.2 Transmitter
Power supply
Voltage supply range
Reverse polarity
protection
Power-up time
Factory settings
Output range
Current limits
Output at sensor fault
Damping
www.baumer.com
85°C
85°C
8 ... 35 V DC
Yes
< 20 s
0 ... 150 °C
Lower: 3.5 mA
Upper: 20.5 mA
23 mA
0.0 s
Operating Instructions
Temperature measurement
TE2
Compact RTD temperature sensor
With cooling neck
Connection code 6
Without cooling neck
Connection code 7
Tamb
Ambient temperature
1
Tp
Process temperature
2
3
4
Output signal
Current output
Shunt resistance
Min. output span
Sampling interval
Damping
Max. conversion
error
Max. output error
Temperature drift
(by ambient)
4 ... 20 mA (2-wire)
Rs ≤ 680 Ohm
(Vs = 24 V DC)
Rs ≤ (Vs – 8 V) / 0.023 A)
25 °C
0.5 s
0.0 ... 30.0 s (programmable)
± 0.25 °C
± 0.1 % FS (± 0.016 mA)
< ± 0.003 % FS / °C typ.
< ± 0.01 % FS / °C max.
11 / 32