28
Possible Errors – code colors
Color code for Error E004
Color code for Error E101
Color code for Error E102
OPERATING MANUAL
Description
The USER INTERFACE and the MAIN BORAD do
have communication troubles.
Comment
This ERROR shows up when a SOFTWARE
UPDATE is loaded to the mainboard. During that
time the Board an`t communicate with the USER
INTERFACE.
Solution
As soon as the SOFTWARE is sent to the MAIN
BOARD the ERROR will be gone itself.
Description
The IGNITION of the Pellets went wrong.
Comment
Mainly the IGNITOR (Heating Cartridge) does
cause this problem.
Solution
Check if the Ignitor does heat up strong enough.
Clean the Burn pot and start the stove. After 6
– 8 minutes there has to be a flame inside if the
ignitor is okay. If you don`t get the flame in that
time period, replace the ignitor.
Description
This ERROR CODE will be displayed when the COM-
BUSTION BLOER of your stove does need to work with
maximium power during Standard Operation or Start Up.
Comment
This ERROR will show up if you stop the stove during the AU-
TOMATIC START UP, if the COMBUSTION BLOWER gets bad
or if the FIRE BOX is untight. ( Door not closed proper, bad
gaskets, ...) Or if the DIFFERNCE PRESSURE TUBES are bad.
Solution
1. Check possible leakage and seal it. 2. Replace the Combus-
tion Blower. 3. Replace bad DIFFERENCE PRESSURE TUBES.