2.1 INSTALLATION OF THE COMPRESSOR AND CONNECTIONS
The floor on which the compressor is mounted should be capable of carrying the weight of compressor
and should be flat and dry. Place your compressor on this surface. There is no need to fixing
(anchorage bolt etc) to the floor.
The compressor room should be easily accessible and sufficiently illuminated.
For adequate service, the compressor room should have a clearance of at least 1.5 m from ceiling and
1m from the wall.
Fire and corrosion causing conditions should be prevented in the operation region.
No pipe load (swaggering connections or tensions arise from environmental variations) should be
relayed to compressor by external connections. For this purpose an outlet hose is being delivered with
your compressor. Connect this hose to right after the outlet vane.
If your air supply is above the compressor level, do not enter the compressor connection pipe to the
main pipe from the bottom. The water formed at the compressor outlet may return back during stopping
and idle operation and may impair the o-rings and gaskets of Minimum Pressure Valve.
Make sure that the air supply equipment is suitable to the operating pressure of the piping and fittings
and is damage free.
Select the diameter of the air supply, dryer and line filters according to your air supply capacity. (It is
beneficially to select piping of big diameter considering future development of your company).
Establish a separate line for condense discharge of your filter and dryer and air tanks (water discharge
line); this way the floor of the compressor operating place does not unnecessarily get wet.
Put an air exit and electric box in your compressor room for general purpose
Your compressor is manufactured for indoor operation. Suitable room set up plan is shown in figure.
In case of different needs in relation to compressor or air supply contact service or sale representative.
HOT AIR DUCT
OUTLET HOSE
OUTLET VALVE
INSTALLATION & ASSEMBLY
PRESSURE GAUGE
COMPRESSOR
SAFETY VALVE
AIR RECEIVER
AIR DRYER
AIR INLET WINDOW
33
AIR OUTLET WINDOW
BYPASS
LINE FILTER
DRAIN LINE