GB

Use other than that intended

Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case of
misuse. If used for purposes other than that intended, our warranty and operating permit will become null and void

CE Manufacturer's Declaration

We declare conformity in the sense of the EC directive, EMC directive (89/336/EEC) as well as the low voltage directive
(73/23/EEC). The following harmonised standards apply: EN 60598-1, EN 60598-2-1, EN 55015, EN 61000-3-2,
EN 61000-3-3
Signature:

Safety information

OASE has manufactured this unit according to the highest quality standards and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accordance
with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recognise
possible danger or who are not familiar with these operating instructions, are not permitted to use the unit!
Please keep these operating instructions in a safe place! Also hand over the operating instructions when passing the unit
on to a new owner. Ensure that all work with this unit is only carried out in accordance with these instructions.
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected and
misused.
Attention! Dangerous ultra-violet radiation.
The radiation of the UVC lamp is dangerous for eyes and skin! Never operate the unit lamp ouside of its housing. Never
immerse the unit in water! Always disconnect the power supply of all units located in water and of this unit prior to
performing work on the unit! Only operate the unit when plugged into an earthed socket. The latter must have been
installed in accordance with the valid national regulations. Ensure that the protective earth wire is led to the unit. Never
use installations, adapters, extension or connection cables without protective earth contact! The cross section of power
connection cables must not be smaller than the rubber cables identified with H05 RNF. Extension cables must meet DIN
VDE 0620. Ensure that the unit is supplied via a fault current protection (FI or RCD) with a reference fault current of 30
mA maximum. Protect the connection cable when burying to avoid damage. Only use cables approved for external use.
Protect the plug connection against humidity/moisture. Never operate the unit if the cable or housing are defective!
Disconnect the power! Do not carry or pull the unit by the connection cable. Electrical installations at garden ponds and
swimming pools must meet the international and national regulations valid for installers. Compare the electrical data of
the supply with those on the unit type plate. This data must agree. For your own safety, consult a qualified electrician if
you have questions or encounter problems! The power connection cable cannot be replaced. If damaged, the unit has to
be disposed of.
Do not operate the unit if persons are in the water! Never use the pump for fluids other than water! Never open the unit
housing or its attendant components, unless this is explicitly mentioned in the operating instructions. Never run the unit
without water!
Attention! The outlet from the filter cannot be more than 2m (0.2 bar water pressure) vertically above the level of
the filter!
Ensure that no leaks at the filter can occur. Danger of completely emptying the pond.

Installation

Place the unit at a flood protected position at a distance from the pond edge of at least 2 m on a firm and level ground.
As an alternative, the filter can be burried up to the recess in the container. Maximum height difference between filter lid
and outlet point: max. 2 m (14). Do not expose the unit to direct sun radiation. Ensure unrestricted access to the cover to
be able to carry out work on the unit.
Installation
Fitting hose connections
The max. pump head height is 5m WC (0.5 bar). Only operate the unit with pressure hoses which are approved at least
for 0.2 bar or the maximum pump pressure. Saw off the stepped hose nozzle at the appropriate point of the corresponding
hoses (13). Push or screw the hoses onto the stepped hose nozzle and secure with a hose clip.
Installation at the water inlet
Push the union nut over the black stepped hose nozzle, fit the hose, insert the flat sealing ring in the union nut, and screw
onto the water inlet socket.
Installation at the water outlet
Push the union nut over the transparent stepped hose nozzle, fit the hose, insert the green flow indicator flag into the
union nut, and screw onto the water outlet socket.
Installation at the cleaning connection
To permanently fit a drain hose to the cleaning connection, unscrew the cover cap from the cleaning connection, push
the union nut over the transparent hose nozzle, fit the hose, insert the green flow indicator flap into the union nut, and
firmly tighten it on the cleaning connection. During filter operation, ensure that the cleaning connection or a drain hose
connected to it is always closed with the cover cap and the inserted flat sealing ring as a security measure, should the
function switch be unintentionally set to „Cleaning". To close the drain hose with the cover cap, push or turn the black
stepped hose nozzle with its thread onto the hose and secure with the hose clip, firmly screw tighten with the flat sealing
ring inserted.
Attention! Never operate the unit without water or without pump strainer casing!