Power and Data Cabling Requirements

AC Power

WARNING: DO NOT connect to three-phase Delta service in countries with 240 volt power.
WARNING: DO NOT connect or disconnect energized power cable at fixture (under load). Turn off
circuit breaker (or completely de-energize circuit) before connecting or disconnecting power cable at
fixture. Power is only removed from the fixture by disconnecting power cable from source or turning
off source circuit breaker.
The luminaire requires standard AC power distribution from 100-240 VAC, 50/60 Hz in order to
power all internal electronics and motors. It is equipped with a 3-pole Neutrik® PowerCon® locking
connector (with contacts for line, neutral, and premating safety grounds) for the purpose of AC input.
Note: The mating Neutrik PowerCon® connector is supplied, however, you will need to purchase or
construct a cable appropriate for your application.
10
L
U
ASH
UMINAIRE
SER
Green/Yellow
*International (Harmonized) Standard
3-Pole Neutrik PowerCon Locking
Connector for AC Input Power
Figure 2-1: Power Connector
07 Au gu st 2009 (Pre limina ry)
'
M
S
ANUAL
Wire*
Connection
AC Ground
Blue
AC Neutral
Brown
AC Line
Neutrik PowerCon
Connector (supplied)
02 .9 690.00 01 0