Inv Pan
Inv Tilt
LED Cor-
rection
LED Setup
LED
Temps
Level
Linear
Manual
Movement
Normal
OFF
Off Time
OK
OK?
ON
Pan
Pan/Tilt
PASS
PROG
Quiet
Re Cal
Red
Reset Def
RS232 Log
RUN TEST
SENS TST
Speed
Square
Law
Start LED
CAL
Status
Swap
02.96 90.000 1 0
Table 4-2: Menu Function Definitions (Continued)
Definition
Purpose
Invert Pan
Reverses pan action for special focus requirements.
Invert Tilt
Reverses tilt action for special focus requirements.
LED Calibra-
Sets LEDs to factory calibration level.
tion Level
LED Opera-
LED settings/operation of power level or calibration.
tional Settings
LED Opera-
Measures temperature associated with LED operation - displays in degrees
tional Temper-
Celsius
ature
Fixture Mode
Luminaire setup is in set fixture mode by user.
Dimming
Sets dimmer operation to standard linear dimming curve
Curve - Linear
Manual
Accesses options for luminaire mechanism control by entry of data values.
Movement
Enables or disables pan and tilt movement.
Fixture Mode
Luminaire setup is in normal fan and LED operational mode. (default)
Off
Turns off a function.
Display off time
Shows the automatic shut-off time for the menu display.
Okay
Indicates calibration has completed and no errors have occurred.
Okay?
Prompt for pressing [Enter] before an action is executed.
On Indefinitely
Sets Menu Display to stay on until programmed otherwise (Display) or turns
on a function.
Pan
Specifies pan function for manual control (Manual) or testing (Test).
Pan/Tilt
Accesses pan and tilt options for focus swap function, movement enable/dis-
able, manual control and testing.
Test Pass
Indicates that a test has passed.
Programming
In the process of programming the luminaire with the new version of software.
Fixture Mode
Luminaire setup is in quiet mode (reduces fan and LED operation for quieter
fixture operation).
Recalibrate
Recalibrates luminaire.
Red LED
Specifies Red (intensity) for manual control (Manual) or testing (Test).
Reset Defaults
Resets default system configuration values.
Factory Use
Sets logging function (ON or OFF) of RS232 data collection (for Factory Use
Only
Only)
Run Test
Indicates that a mechanism test is in progress.
Sensor Test
Indicates that a system sensor test is in progress.
Pan/Tilt Speed
Selects or sets pan and tilt operational speed.
Dimmer Curve
Sets dimmer operation to IES square wave dimming curve
- Square Law
Factory Use
Only
WARNING: For factory use only - DO NOT use OR select, "Start
LED Cal".
Status/Error
Allows scrolling through error list or displays OK if no errors.
Swap
Swaps pan/tilt action for special focus requirements.
07 Au gu st 2009 (Pre limina ry)
M
S
: M
ENU
YSTEM
ENU
4
F
UNCTIONS
49