VL880 Spot Control Channel Functions
Notes:
•
When resetting fixtures to Defaults, settings in Bold will be activated.
•
DMX values not shown are for future use.
•
Full Luminaire ReBoot will douse lamp and restart the Main Control Board (MCB).
†
•
* Note that these functions do not require the 3 second rule to execute. All other values do require
3 second rule.
02.96 87.000 1 C
Table 12: VL880 Spot Control Channel Functions
Control Channel Function
Default Console Value (Idle)
Display - Menu Settings / Off
Reset Fixture to Defaults
Edge Track ON
Edge Track OFF (Norm)
Color Snap ON
Color Snap OFF (Norm)
Dimmer Snap ON
Dimmer Snap OFF (Norm)
Motor Mini-Stepping ON / OFF
Iris 1 Installed
Iris 2 Installed
Full Luminaire Recal
Full Luminaire Reboot
†
Recal Color
Recal Gobo
Recal Beam
Recal Dim / Strobe
Lamp OFF
Lamp Strike
31 Octo be r 20 13
O
: L
PERATION
UMINAIRE
Control Channel Value (VL880 Spot Only)
DMX Value
0
3 - 4
5 - 7
11 - 13
14 - 16
20 - 25
30 - 35
40 - 45
50 - 55
60 - 65
70 - 72
73 - 75
81 - 87
91 - 97
100 - 104
112 - 116
126 - 130
138 - 142
165 - 171
249 - 255
3
T
IMING
After 3 Secs
0
0
0
N/A*
N/A*
N/A*
N/A*
N/A*
N/A*
0
0
0
0
0
0
0
0
0
0
0
57