Assembly
The fitting must be installed, flushed and
tested after the valid norms!
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in
position on the basin / bidet.
3. Slip the fixation piece including the washer over
the threaded pins and tighten the nuts.
4. Connect the supply pipes to the isolation valves;
cold right - hot left.
5. Connect the pull rod to the pop-up waste.
The hot and cold water supply's should be of equal
pressures.

Operation

The mixer is activated by lifting the lever handle.
Move to the left = hot water,
move to the right = cold water.
Technical Data
This mixer series-produced with waterdim-
mer (flow limiter)
Rate of flow with waterdimmer:
Rate of flow without waterdimmer: 12 l/min 3 bars
Operating pressure:
Recommended operating pressure: 1 - 5 bars
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Hansgrohe single lever mixers can be used together
with hydraulically and thermically controlled con-
tinuous flow heaters if the flow pressure is at least
1.5 bars.
If the continuous water heater causes any problems
or there is not enough flow of water, the waterdimmer
(6a) located behind the aerator must be removed.
6
English
To adjust the hot water limiter on single lever mixers,
please see page 13.
No adjustment is necessary when using a continuous
flow water heater.
Spare parts (see page 5)
1
1.1 screw cover
2
3
4
5
6
7
7.1 diverter knob
7.2 pull rod
8
9
Special accessories
X
7 l/min 3 bars
max. 10 bars
16 bars
max. 80° C
65° C
handle
flange
nut
cartridge cpl.
locking screw
aerator cpl.
pop up rod
fixation set
connection hose 450 mm
special tool set
(not part of delivery)
33891000
96338000
94192000
94194000
92730000
96059000
13912000
92620000
94066000
94067000
96016000
95001000
58085000