Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
Centre distance:
Connections G 1/2:
The product is exclusively designed for drinking water!
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
max. 70°C / 4 min
150 ± 12 mm
cold right - hot left
Assembly see page 32
Symbol description
Do not use silicone containing acetic acid!
Operation (see page 35)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Adjustment (see page 34)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions (see page 31)
Flow diagram
(see page 31)
with EcoSmart
without EcoSmart
Spare parts (see page 36)
Cleaning
see enclosed brochure.
®
®