25. Fault rectification

If a problem occurs when the CRR 320 is actively con-
nected to the software, both the software and the
CRR 320 must be re-started.
Possible faults:
R
Low battery charge
R
Cable connection between CRR 320 and PC discon-
nected without previously deactivating the link in the
software.
Link established with wrench
Link not established with wrench
In the event of problems with the link:
1. Check whether the CRR 320 is switched on.
2. Check whether the cable is properly connected.
3. Check whether the wrench is in Track, Peak or Pre-
set mode.
4. In the case of a USB connection, check whether a
corresponding driver has been installed in the PC.
Robert Bosch GmbH
Fault rectification | CRR 320 | 45

26. Technical data

Torque range:
Deviation:
Angle range:
Deviation:
Tool holder:
Md measurement system:
Modes of operation:
Md resolution in display:
DEG resolution in display:
Power supply:
Battery type:
Service life:
*Not included
Keys:
Display:
Visual indicator:
Acoustic indicator:
Sensory indicator:
Housing:
Interface output:
Interface type:
Baud rate:
Interface connection:
Number of memory locations:
Work schedule:
Curve plotting:
en
4...150 Nm
max. +/- 1%
0...999°
max. +/- 1%
9 x 12
Bending beam
Track / Peak / Preset / Angle
0.1
0.1
Batteries/ Storage Batteries*
Alkaline/NiMh mig-
non (AA, LR6)*
approx. 8 hours
6 + 1
Graphical LCD 20
x 4 characters
LED progress bar
Signal generator
Vibrator
Aluminium
Axial
RS 232
38400
3.5 jack
2000 data registers
100
50 (plotting time: 10 sec.)
|
0 986 629 502
2015-02-16

Werbung