Problem
Final vacuum is
poor
The cover does not
open
If the machine does not work properly after
the above-mentioned checks, contact the
assistance service describing the detected
defect.
Error
Eprom Error.
E0
The main board is faulty.
Contact the technical assistance service.
Data configuration error.
ER1
Contact the technical assistance service.
Calibration error.
ER2
Re-adjust the control board through a suitable vacuum gauge.
Contact the technical assistance service.
Cycle counter error.
ER3
Contact the technical assistance service.
Faulty sealing relay.
ER4
Contact the technical assistance service.
Vacuum Timeout: overtime.
Ensure the set vacuum percentage is correct.
ER5
Ensure the cover gasket is not dirty or worn.
Make sure the cover closes correctly.
Oil maintenance.
The machine has exceeded the number of cycles beyond which oil replacement is
ER7
required.
Contact the technical assistance service.
Disposal of the packaging
The packaging bears the Green Point mark.
Dispose of all the packaging materials such
as cardboard, expanded polystyrene and
plastic wrapping in the appropriate bins. In
this way you can be sure that the packaging
materials will be re-used.
Cause
 The blade placed under the Teflon
of the sealing bar is broken.
 The set vacuum percentage is
incorrect.
 The cover gasket is dirty or worn.
 The cover is not closed correctly.
 No power supply.
 Replace the blade (contact the Technical
Assistance Service for a replacement).
 Change the vacuum percentage.
 Clean or replace the cover gasket (contact the
Technical Assistance Service for a
replacement).
 Close the cover correctly.
 Make sure that objects or dirt are not found
between the cover and tank.
 Wait until the power supply is restored.

ALARM MESSAGES

The circuit board detects some alarms,
which are displayed with the following
messages:
Solution
Disposal of equipment no longer used
According to European Directive 2012/19/EU
on the management of waste electrical and
electronic
equipment
electrical appliances should not be put into
the normal systems for disposal of solid
urban waste.
english