Procedure:
Step 1: Unscrew the 3 lower fixation screws of the top part of the housing.
Step 2: Remove the top part of the housing slowly and carefully.
Step 3: Remove the lamp-sockets from the lamps.
Step 4: Unscrew the fixation screw of the lamp holder.
Step 5: If replacing a lamp, remove the old lamp from the top part of the housing.
Step 6: Insert the 12 V/50 W GX-5,3 MR-16 lamps into the top part of the housing.
Step 7: Replace the lamp holder and tighten the screw.
Step 8: Replace the lamp-sockets onto the lamps.
Step 9: Replace the top part of the housing and tighten the screws.

Rigging

Install the device in a well-ventilated area. The operation in an unsufficiently ventilated room can lead to an
overheating of the device. The resulting overheating of the device can cause accidents. Keep a minimum
distance of 0.5 m around and above the device.
This device is only constructed for a standing installation.
This device may only be used as an integrated lighting fixture in 3-Point Trussing Systems with Quicklock.

DMX-512 connection / connection between fixtures

The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.
Do not operate this device with opened top part of the housing!
the fixtures will not work at all, or will not work properly.