Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - HANSGROHE Croma Showerpipe 27169000 Montageanleitung

Vorschau ausblenden Andere Handbücher für Croma Showerpipe 27169000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Important! The fitting must be installed, flushed and
tested after the valid norms!
The hot and cold supplies must be of equal pressures.
Assembly (see page 35)
Gloves should be worn during installation to prevent crush-
ing and cutting injuries.
Where the contractor mounts the product, he should ensure
that the entire area of the wall to which the mounting plate
is to be fitted, is flat (no projecting joints or tiles sticking out),
that the structure of the wall is suitable for the installation
of the product and has no weak points.
The enclosed screws and dowels are only suitable for
concrete. For another wall constructions the manufacturer's
indications of the dowel manufacturer have to be taken
into account.
In case of emergencies, the lower part of the pipe can be
shortened by means of a fine saw.
The filter insert (A) must be used to ensure the standard
flow rate and to protect the hand shower against incom-
ing dirt by pipework. Do you want a larger water flow
rate, then you must use the filter packing (B) instead of
the filter insert (A).
Incoming dirt leads to defects or/and can damage parts
of the hand shower; such caused faults voids all liability
and guarantee claims. (see page 39)
Correction is necessary if the temperature measured at the
take off point differs from the temperature set on the scale.
To adjust please see page 42
The desired maximum temperature for example max.
42 C can be pre-set thanks to the safety function. (see
page 40)
The arm of the shower head is intended only to hold the
shower head. Do not load it down with other objects!

English
Important! The non return valves must be checked
regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
To guarantee the smooth running of the thermostat, it is
necessary from time to time to turn the thermostat from
total hot to total cold.
The product may not be used as a holding handle. A
separate handle must be installed.

Technical Data

Operating pressure:
Recommended operating pressure: 0,15 – 0,5 MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.: 65°C
Centre distance:
Connections G ½":
anti-pollution function
Hansgrohe showers can be used together with hydraulically
and thermically controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa before the shower fitting.
Spare parts (see page 3)
Operation (see page 43)
The shower system may only be used for bathing, hygienic
and body cleansing purposes.
Children as well as adults with physical, mental and/or
sensoric impairments must not use this shower system without
proper supervision. Persons under the influence of alcohol
or drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body
parts (such as your eyes). An adequate distance must be
kept between the shower and you.
Cleaning (see page 44)
max. 1 MPa
1,6 MPa 65°C
max. 80°C
150 mm
cold right - hot left

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis