10. Troubleshooting

10.1. Error message display

All repair and servicing work must be carried out by qualified service technicians or a
firm specifically authorized by the manufacturer.
An error message appears as the two right-hand
figures in the session-time display (e.g. 92).
service
The "
" symbol
the error message.
The control system can operate for as long as the
service
"
" symbol
flashes.
The error message is displayed alternately with the
sauna program.
No.
Error
85
Broken lead on main board/front board.
86
Broken lead on IR sensor.
87
Short-circuit on IR sensor.
88
Heating element defective.
95
Broken lead on current-temperature sensor.
96
Broken lead on stove-temperature sensor.
97
Safety temperature limiter (STL) interrupted.
98
Short-circuit on current-temperature sensor.
99
Short-circuit on stove-temperature sensor.
92
Vaporizer requires deferring.
PAGE 50
flashes together with
Error remedy
Disconnect control system from power
supply.
Do not enter cabin!
'
Contact customer service.
Service vaporizer.
'
See operating instructions
Article no. 50701117.