5.
Assemble the control system
5.1.
Assemble and connect the control system housing
Assemble and connect the bottom section of the
housing
1.
Thread each wire in from the back, through its
own plastic sleeve and via the bottom section of
the housing, following the connection order
indicated.
2.
Secure the bottom section of the housing using
the four built-in screws.
3.
Connect the control system in accordance with
the wiring diagram.
'
See chapter 7.
.
Use insulated 5-6 mm terminals to ensure that the
system is wired up correctly. Ensure that no wires
are left protruding.
.
Use a screwdriver to release the terminals before
inserting the wires.
4.
Check the wiring to ensure that it has been
connected correctly.
5.
Insert plug into board socket.
6.
Place the front section on the bottom section of
the housing and push it until it engages in
position.
'
Establish the type of sauna in the Service menu
when starting up the system - see section 9.3.
5.2.

Connect the power unit

Connect the power unit
1.
Remove the two fixing screws from the split
housing cover and detach the cover.
2.
Connect the power unit in accordance with the
wiring diagram.
.
Use insulated 5-6 mm terminals to ensure that the
system is wired up correctly.
.
Ensure that no wires are left protruding.
.
Use a screwdriver to release the terminals before
inserting the wires.
3.
Check the wiring to ensure that it has been
connected correctly.
4.
Refit the housing cover and secure with the two
fixing screws.