9.
System parameters
9.5.

Service menu 06/07, temperature offset

Entry value:
Entry range -5 °C to +5 °C in steps on one degree.
Use the up/down keys
Press the button
to confirm the selection.
If the temperature-offset value is in the "plus" range, the STL may suffer long-term
damage.
9.6.

Service menu 08, power unit detection

With an output of >3 kW.
Entry value:
Use the up/down keys
0
=
inactive
Press the button
to confirm the selection.
9.7.

Service menu 09, interrupted end-of-session drying

Display value:
The session-time display shows the number of end-of-session drying operations interrupted by the user
after operation in SANARIUM mode.
9.8.

Service menu 10, read error

Display value:
Use the up/down keys
The first number is the error code of the selected message (flashing at 1 Hz).
The following three figures indicate the fault index number (flashing at 2 Hz).
An error index of 255 indicates that no error code is entered.
9.9.

Service menu 11, delete error

Entry value:
Use the up/down keys
0
=
don't delete
Press the button
to confirm the selection.

9.10. Service menu 12, activation hours

Display value:
The session-time display indicates the time (in hours) since the control system was connected to the
mains power supply.
PAGE 48
to select the value.
to select the power unit detection function.
to access details of the last five errors to occur.
to select the delete error function.
1
=
active
(requires a separate power unit)
1
=
delete
Comfort Control
50701118/10.05

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis