1.

Use for intended purpose

The control system is designed for use with sauna stoves (with or without vaporizer), which have been
tested and approved by the Association of German Electrical Engineers (VDE) or TÜV.
Use the control system for its intended purpose only. This includes observance of the manufacturer's
specified operating, assembly and servicing instructions. The manufacturer can accept no liability for
loss or damage resulting from incorrect operation of or unauthorized modifications to the control
system. The user bears sole responsibility in this case.
The control system must only be operated, serviced and maintained by persons who are suitably
trained for the purpose and familiar with the hazards involved. Observe the corresponding VDE
specifications (or your local equivalents), along with any applicable generally-recognized technical
standards.
2.

General safety precautions

Read and observe the operating instructions and safety precautions before starting up for the first time.
All items in these assembly instructions that concern your personal safety are marked
with this symbol. Make a copy of the safety precautions available to other users.
d
Always assemble the control system away from the sauna cabin!
d
Disconnect the control system from the mains supply before removing the control-system housing.
d
The control system must be connected to the mains supply by a locally-authorized electrician.
d
Sauna and SANARIUM units must be hard-wired into the mains electrical system in accordance
with the specifications of the Association of German Electrical Engineers (VDE) or your local
equivalent. Fit a I
nN
3 mm to the power supply line.
d
Contact customer service if a malfunction cannot be dealt with by an approved electrician.
d
Use only original spare parts.
d
Do not carry out unauthorized modifications to the control system.
d
Assemble the control system in accordance with the assembly instructions.
d
Electrical cables running inside the cabin and its walls must be sealed with silicon.
d
Always ensure, before putting the control system into service, that there are no flammable items
on or near the stove. FIRE HAZARD!
3.

Technical specifications Comfort Control system

Comfort Control: 230 V, 50-60 Hz, max. 3 kW
Dimensions: W = 330 mm, H = 240 mm, D = 90 mm
Room conditions: Temperature 0 ºC - 40 ºC, air humidity max. 80 % rel. hum.
50701118/10.05
≤ 0.03 A fault-current circuit breaker with a minimum contact opening of