Downloaded from www.watergardeningdirect.com
Removing/cleaning the pump
Prerequisite: The tank is open.
How to proceed:
 M
1. Unscrew the plug connection and pull apart.
– Protect the open plug connection from moisture.
2. Unscrew the Storz coupling type C.
3. Turn the adapter away to the side.
4. Remove the transport protection.
5. Carefully bend open the retaining brace with the tab to release.
6. Remove the discharge pump and clean or replace if defective.
7. Cleaning the discharge pump:
– Undo the screws on the pump casing and remove the protection grid.
– Clean the protection grid and pump casing on the inside and outside with clear water and a soft brush.
– Remove soiling from the impeller unit, turning the impeller unit by hand to access all soiled points.
8. Reassemble the parts in the reverse order.
– The transport protection only needs to be fitted for shipping or horizontal transport of the unit.

Wear parts

The following components are wear parts and are excluded from the warranty:
 Foam filter
 Debris collection bag
 Seals
 Wheels
 Non-return valve
 Impeller unit
Storage/Over-wintering
 Drain the unit as far as possible, clean thoroughly and check for damage.
 Empty all hoses, pipes and connections as far as possible.
 Store the unit in a dry and frost-free place.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.