In case of adjustment or repair on the compressor electrical component; ensure that your feet are not
wet and try to stand on an insulated place such as a wooden pallet.
Try to make all kinds of repair and adjustment work with single and with right hand if possible.
Therefore, the risk of flowing electrical current from the hearth in case of shock is minimized.
Make repair and adjustment work at a well laminated, dry, clean and in good ventilated environments.
Always keep the electric cabin's door closed. If you need to open it; stop the compressor and remove
electrical power from main circuit breaker.
During the start up, check all equipments and it connections again.
1.9 LIFTING AND HANDLING THE COMPRESSOR
Lift the compressor by forklift. The forklift blade entry place at the bottom is easy to see.
Before lifting the compressor, make sure that the forklift blade is well balanced.
Ensure that he forklift does not lift the compressor excessively; move slowly and carefully.
If you should lift the compressor with palette, ensure that the compressor is fixed to the palette first.
Never lift the compressor, if the compressor is not properly mounted on the palette or the connections
are damaged. Otherwise, you may cause injuries and damage.
If the forklift is not available, lift it by crane as shown in figure.
Before lifting the device, make sure that no damage or rupture at the welding points that the lifting belt
will pass.
Retighten the bolts and screws that may be loosened during transportation.
Make sure that all kinds of lifting belts, hooks etc. are in good condition and capable of carrying the
weight of compressor. If you do not know the weight of the compressor, check it.
Be careful to avoid the damage of compressor. In case of bumping and falling, damage may occur at
the internal components of compressor.
Make sure that there is no body underneath the compressor during lifting. Be careful.
Do not over lift the compressor.
The operator carrying out the lifting process should see the compressor while suspended.
Make sure that the floor of the compressor is strong enough to carry the compressor weight.