Problem
Water is collected
in the drain channel
and is not removed
correctly
The door seal
sticks during
opening
Water under the
refrigerator
The surface of the
refrigerator is
steamed
The malfunctions listed in the table above are only for reference purposes and
should be considered examples. If the aforementioned or other problems occur,
immediately turn the device off and stop using it. If the malfunction cannot be fixed,
contact a service centre or sales agent.
Cause
• Clogged hole in the
condensate drain channel
• The door seal is contami-
nated with the sticki food
product (grease, syrup, etc.)
• The condensate tray fell
from the compressor
• The environment air
humidity exceeds 70%
Solution
• Clean the drain hole
• Wash the seal with water
and gentle cleaning agent
and thoroughly dry
• Place the condensate
tray on the compressor
• Ventilate the room where
the refrigerator is installed
and remove the reason of
excessive humidity
- 43 -