HANDLING

Carefully remove the adhesive strips from the appliance.
After having removed the packaging, check that the con-
tents are intact and complete.

INSTALLING THE INDOOR UNIT

Before starting installation, decide on the position of the
indoor and outdoor units, taking into account the mini-
mum clearance required around the units (see technical
data table).
Install the indoor unit in the room to be air conditio-
ned, avoiding installations in corridors or communal
areas.
Ensure that there is a mains socket very close to the
indoor unit where it can be plugged in.
Install the indoor unit at a height of at least 2.5 m
from the ground.
LOCATING THE INDOOR UNIT
The indoor unit must be wall mounted.
It must be located so that the treated air can circula-
te throughout the room.
To install the indoor unit proceed as follows:
Installing the mounting plate
-
Remove the screws from the plate, which is attached to
the rear of the unit.
-
Remove the plate;
-
Place it against the wall at the point where it is to be
installed, using a spirit level (provided in the kit) to
ensure that it is horizontal and complying with the mini-
mum clearance indicated in the figure.
-
Using a pencil, mark the position of the holes for the
screw anchors on the wall.
-
Drill 32 mm deep holes in the wall for fixing the plate.
-
Insert the plastic anchors into the hole.
-
Fix the mounting plate to the wall using the anchors
and the self-tapping screws provided in the kit.
-
Check that the mounting plate is correctly fixed.
-
Check again that the plate is level.
Drilling a hole in the wall for the piping
-
Decide where to drill the hole in the wall for the piping
according to the position of the mounting plate (see
figure)
-
Using compasses, mark the circumference (ø 90 mm) of
the hole for the connections to pass through.
The hole must be drilled in the left side of the unit in
line with the refrigerant outlet connections.
SINGLE SPLIT
The outdoor unit must always be kept upright.
Handling must be done by suitably equipped qualified
technical personnel using equipment that is suitable for
the weight of the appliance.
Recommended minimum clearance
Outline of the unit
150 mm
Note: when the product is delivered the mounting plate
is attached to the rear of the indoor unit. It may be a dif-
ferent shape to the one shown above, but the method of
installation is the same.
M o u n t i n g
plate
4,1x32
4,1 x 32
Plate (wall-
mounted)
( Ø 9 0 m m )
USER
USER
150 mm
150 mm
Plastic anchor
ENGLISH
11