Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic ADC0309H3E5B Installationsanleitung Seite 12

Air-to-water hydromodule + tank
Vorschau ausblenden Andere Handbücher für ADC0309H3E5B:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 225
APPENDIX
1 Variation of system
This section introduces variation of various systems using Air-To-Water Hydromodule + Tank and actual setting method.
1-1 Introduce application related to temperature setting.
Temperature setting variation for heating
1. Remote Controller
Outdoor
Connect fl oor heating or radiator directly to the Tank Unit.
Remote controller is installed on Tank Unit.
This is the basic form of 2 zone system.
2. Internal Room Thermostat
Outdoor
Connect fl oor heating or radiator directly to the Tank Unit.
Remove remote controller from Tank Unit and only can be install it in room 1 or room 2.
This is an application that uses remote controller as Room Thermostat.
3. External Room Thermostat
Outdoor
Connect fl oor heating or radiator directly to Tank Unit.
Remote controller is installed on Tank Unit.
Install separate external Room Thermostat (fi eld supply) in the room where fl oor heating is installed.
This is an application that uses external Room Thermostat to control room temperature.
12
Indoor
Tank Unit receive Room Thermo signal (ON/OFF) from Remote controller
to control HP and circulation pump.
There is a build-in thermistor in the remote controller.
Indoor
Indoor
Room Thermostat
(Field supply)
Floor heating 2
Floor heating 1
Floor heating 2
Floor heating 1
Floor heating 2
Floor heating 1
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - Yes
Zone and Sensor - 2 Zone system
Zone 1 Sensor:
Room
Water temperature
Zone 2 Sensor:
Room
Water temperature
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - Yes
Zone and Sensor - 2 Zone system
Zone 1 Sensor:
Room thermostat
Internal
Zone 2 Sensor:
Room
Water temperature
Setting of remote controller
Installer setting
System setup
Optional PCB connectivity - Yes
Zone and Sensor - 2 Zone system
Zone 1 Sensor:
Room thermostat
External
Zone 2 Sensor:
Room thermostat
External