5.4

Wiring diagram EA25/45/120/250

Standard actuators: Provided with DIN-Plugs EXW. Follow diagrams below.
cUL marked actuators: Provided with cable glands. Connect open wired
open close
1 2 3 4 N
green
1
Connection of the voltage supply for positions OPEN, CLOSE and MIDDLE
Ready to
operate
COM
NO NO NC NO NC COM NO NC
5 6 7 8 9 10111213
Relay ratings:
Relays: Max. 6A @
either 230VAC or
24VDC
red
Caution: Do not mix
24VDC and 230VAC!
Apply only one
1
voltage-level!
Connection of position feedback for positions OPEN, CLOSE (MIDDLE optional)
Do not connect mixed voltage potentials or voltage sources on the feedback relays.
Either connects 230VAC or 24VDC the feedback relays. Do not connect 230VAC and
24VDC at the same time. Also ensure the voltage is supplied from one single source
to all relay contacts at all times.
directly to Terminals 1-N.
permanent
middle
red
black
2
3
open
close
white
black
2
3
connection
terminals
PE – Protective
Earth IEC60364
green/yellow
connector
middle
Connection
terminals
green
Connector
4