GND
18
LUX
NC safety input (photocell). Enter the programme wanted with dip switches 4 and 5.
LUX
19
It triggers only in the closing phase; it never triggers in opening.
AUX
AUX
24
NC safety input (photocell).
The AUX input is for an additional photocell and it refl ects the functions set.
GND
25
R
REVERSER
30
GND
E
It is supplied already wired and tested. It triggers only in the closing phase when the bar knocks against an obstacle. Enter
V
E
+12
31
the programme wanted with dip switches 7 and 8.
Vcc
R
Connect the brown wire to terminal 30, the green to terminal 31 and the white to terminal 32.
S
E
Check: that when the reverser disc is turned slowly the REV LED fl ashes.
32
REV
R
FCA
20
FCA
Limit switch N.C. input in opening. When activated the opening travel fi nishes.
GND
22
FCC
21
FCC
GND
Limit switch N.C. input in closing. When activated the closing travel fi nishes.
22
GND
42
RUN
N.O. input that allows the automation to be controlled according to a logic programmed with dip switches 1 and 2.
43
RUN
OPEN
OPEN
9
N.O. input - opening only Connect clocks, daily timers or weekly timers here if wanted.
By keeping this input controlled, the automation performs the opening manoeuvre and will close automatically only when the
GND
input is freed.
8
GND
STOP
8
N.C. safety input. When activated it stops the automation instantly and a subsequent start always cause reopening. During pause
STOP
time (PAUSE trimmer) a stop command disables automatic reclosing, leaving the bar open waiting for commands. NOTE: The
7
hatch microswitch is already connected to this input and it is possible to connect the pushed bar kit as well as an accessory.
CLOSE
10
CLOSE
N.O. input for closing. It allows the automation to be closed only if the safety devices have not triggered.
GND
8
40

EXTERNAL RESET

To be able to block all functions and reset the control unit at its initial conditions there is a NO contact on terminals 40-41: to
add the function, position dipswitch 10 ON and connect either a switch or key selector to the terminals.
41
The O&O model radio receivers can be plugged into connector J2.
Board for controlling the bar by means of radio transmitters.
Plug the radio receiver board (RX1) into connector J2 and read the enclosed instructions.
The radio signal acts as a Start command. It is also possible to use the radio board RX2; in this case jumper PT1.
Connect the wired antenna, if any, to the radio receiver's antenna terminal.

10.3 INPUTS CONTROL TERMINAL BLOCKS

11. PLUG-IN RADIO RECEIVER

- 14 -
terminals 18 - 19
terminals 24 - 25
terminals 30 - 31 - 32
terminals 20 - 22
terminals 21 - 22
terminals 42 - 43
terminals 9 - 8
terminals 7 - 8
terminals 10 - 8
terminals 40 - 41