Replacing the fuse

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rear panel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Dimensions:
Weight:
Maximum ambient temperature T
Maximum housing temperature T
Min. distance from flammable surfaces:
Min. distance to lighted object:
Fuse:
Accessory:
OSRAM HSR 1200/2 100V/1200W G-22 800h
PHILIPS MSR 1200 100V/1200W G-22 800h
Please note: Every information is subject to change without prior notice. 26.03.2009 ©
230 V AC, 50 Hz ~
1650 W
1000 x 250 x 310 mm
33 kg
:
45° C
a
(steady state): 120° C
B
0.5 m
3 m
F 15 A, 250 V
Best.-Nr. 89109010
Best.-Nr. 89109015
18/18