The Axis product is supplied with an optional dome. To replace the dome cover:
1. Loosen the 4 screws under the dome cover that hold the dome in place.
2. Replace the old dome with the new. Make sure the rubber gasket sits securely in place
and tighten the screws.
Mounting Bracket
The mounting plate has 4 mounting patterns (A,B,C,D). The mounting patterns follow the standard
for the following mounting options:
A: 4" square box
B: standard-sized US double gang junction box
C: 4" octagon box
D: standard-sized US single gang junction box
Route the Cables
Depending on whether you want to route the cables through or along the wall, follow the relevant
instructions below. To route cables along the wall:
1. Using the drill template drill 4 holes in the wall.
2. Attach the mounting bracket to the wall using 4 screws appropriate for the wall material.
3. Remove the camera unit from the unit casing by pushing the springs aside.
4. Remove the gaskets from the side holes in the unit casing. If there is only one cable,
remove only one gasket.
5. Place the unit casing on the mounting bracket and attach it by tightening the four screws.
6. Pull the cables up through the side holes in the unit casing.
7. Drag the gaskets along the cable and plug them into the holes. The gaskets should fit
snugly in the holes with no folds or bends.
8. Re-attach the top part of the cable shield by tightening the two screws.