Herunterladen Inhalt Inhalt Diese Seite drucken

Fire Safety - Kirami Original Woody Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Original Woody:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 30
Fastening the stove
Depending on the model of the product, the stove is supplied
separately or fastened. Inner stoves SUB and SIDE are usually
fastened at the factory (sometimes separately due to
transportation). In case the product has been supplied on its
side (usually only abroad), the protective fence of these
stoves is separate and it shall be fastened with the supplied
screws. The drink holder of the SUB and SIDE is attached to
the protective fence.
The external CUBE and TUBE stoves are delivered disconnected and there are model-specific
instructions and equipment in the stove package. Ensure the water-tightness and fastening to the
tub. Optional model-specific drink holder/protective plate through which fastening the stove can
be made. On an even surface, there should be approx. 20 mm of space for the support below the
stove. However, the proper height of the support should always be checked at the installation site.
chimney. When near a roof or when running the chimney through the roof, the end of the insulated
chimney needs to be one metre above the roof.
Pay attention to the fire safety of the hearth in stoves of normal furnaces (SIDE, CUBE, TUBE),
there cannot be inflammable material located in front of and below the hearth. In practical terms,
this means that an area of incombustible material, such as concrete, sand, or a metal plate, is
needed in front of the hearth. The stove will not heat up above the water temperature as the stove
is surrounded by a water jacket. The chimney and door of the stove will heat up, however. Ask more
from a local fire authority.
Flue
Be careful, the edges of the chimney are very sharp. Use protective gloves! The
chimney is delivered in a separate box and it consists of four parts (picture on
right) and it needs to be assembled. Remove the protective film from the thermal
protection and place the assembled chimney to the chimney outlet of the stove.
INSTRUCTIONS FOR USE: Kirami Original Woody
23/68
In case the tub is placed near
buildings, e.g. the edge of a terrace,
ensure that the chimney is located
away from flammable materials.
Remember to check the distance
both sideways and vertically to
avoid the risk of fire. The distance
should be three metres sideways
away from any flammable material.
A smaller dimension is sufficient for
the chimney. In case the chimney is
closer, use a separately insulated
27.02.2016

FIRE SAFETY

3 / 9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis