Installation instructions

Assembly by a technician only!
Always read and follow the installation instructions.
The DuoControl automatic changeover regulator may
not be installed in EX zone 0 (such as in tank trucks).
In vehicles from construction date 01/2007 using the
DuoControl changeover regulator, the gas cylinders must be
closed while driving. Apply the enclosed stickers in the
cylinder box and in the vicinity of the liquid gas heater control
panel.
Always give the operating instructions to the operator!

Installation dimensions

52
59
30

DuoControl installation and connection

DuoControl should be installed so that the high-pressure hose
connections are in the highest possible position, and at least
above the cylinder valve level (broken line).
The high pressure hoses must be installed with a perment
slope towards the cylinder outlet.
regulator, particularly while driving.
133
63
The DuoControl changeover regulator must always be in-
stalled in such a way that the high-pressure hose connections
56
are arranged in a horizontal position.
Installation above the cylinder valves makes it more diffi-
cult for gas in the liquid phase to get into the changeover