Installation instructions
The appliance may only be installed and repaired by an
expert. Read the installation instructions carefully before work
and follow them.
Non-compliance with installation instructions or
incorrect installation can result in endangerment
of persons and property.
Intended use
The electrical auxiliary heater Ultraheat is suitable for installa-
tion in an S 3004, S 3004 P, S 5004 or S 5004 E (NL) heater.
The auxiliary heater is attached to the heater's installation box
between the installation box and heat exchanger. A 230 V ~
50 Hz (8.5 A) power supply is required to operate the auxiliary
heater.
Other forms of use are also possible after consultation with
Truma.
Declaration of conformity
The electrical auxiliary heater Ultraheat has been tested by
the DVGW and is entitled to bear the CE symbol. (Declaration
of conformity – see operating instructions for the respective
heater).
The CE Product Identity Number of the heating system remains
valid without change.
Regulations
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
modifications to the unit (including accessories),
modifications to the exhaust duct and the cowl,
failure to use original Truma parts as replacement parts and
accessories,
failure to follow the installation and operating instructions.
Furthermore, the approval for operating the appliance will
become invalid and in some countries also the approval for
operating the vehicle.
Retrofitting
When an electrical auxiliary heater Ultraheat is retrofitted, the
heater, the installation box and fan also need to be disman-
tled; this may only be carried by a specialist.
After these parts are dismantled, the auxiliary heater is in-
stalled into the installation box as described in „First-time
installation".
Before re-connecting the exhaust duct, a new O-ring (34)
must be fitted.
6
34
First-time installation
S 3004, S 3004 P
Break out perforated section (U) on the exterior of
installation box (1) for passing through the control
electronics.
Insert heating element (70) from the inside of installation box (1)
and fasten by means of six B 3.5 x 9.5 mm screws.
Mount the installation box (1) and fan TEB-3 or TN-3 as
described in the heater's installation instructions.
3 x (3,5 x 12)
70
Proceed installing the heater installation process as described
in the installation instructions of the respective heater.
S 5004, S 5004 E (NL)
Break out perforated section (U) on the exterior of instal-
lation box (1) for passing through the control electronics.
Break out the lower part of the interior of installation box (2) at
perforation (2a).
Insert heating element (70) from the inside of installation
box (1) and fasten by means of six B 3.5 x 9.5 mm screws.
Mount the outer part of the installation box (1), the inner part
of the installation box (2) and the fan TEB-3 or TN-3 as de-
scribed in the heater's installation instructions.
3 x (3,5 x 12)
70
2
2a
Proceed installing the heater installation process as described
in the installation instructions of the respective heater.
1
6 x (3,5 x 9,5)
U
1
6 x (3,5 x 9,5)
U