Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressu-
res.
Installation Instructions
•
The fitting must be installed, flushed and tested after
the valid norms!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
anti-pollution function
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
English
Symbol description
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly see page 7
Maintenance (see page 11)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
To adjust the hot water limiter on single lever
mixers, please see page 9. No adjustment
is necessary when using a continuous flow
water heater.
Do not use silicone containing acetic acid!
Dimensions (see page 6)
Flow diagram (see page 8)
Spare parts (see page 12)
Operation (see page 10)
Cleaning (see page 11) and
enclosed brochure
If the waterflow drops, clean the filter
located between hose and handspray.