5. Transport, packaging ... / 6. Commissioning, operation

5. Transport, packaging and storage

5.1 Transport
Check pressure gauge for any damage that may have been caused by
transport. Obvious damage must be reported immediately.
GB
5.2 Packaging
Do not remove packaging until just before mounting.
Keep the packaging as it will provide optimum protection during trans-
port (e.g. change in installation site, sending for repair).
5.3 Storage
Permissible conditions at the place of storage:
Storage temperature: -30 ... +80 °C
Protect pressure gauges from moisture and dust.

6. Commissioning, operation

Installation and mechanical connection
In accordance with the general technical regulations for pressure
gauges (e.g. EN 837-2 "Selection and installation recommendations for
pressure gauges").
Process connection bottom or rear
Protect pressure gauges from contamination, high temperature
changes and vibrations
air2guide standard gauges are calibrated in vertical position and
should be installed in the same position to avoid loss of accuracy.
If a different installation position is required please specify when
ordering. Gauges with high pressure ranges can be installed in
different non-vertical mounting position, by simply adjusting the zero
point.
8
WIKA operating instructions air2guide models A2G-10, A2G-15