3. Specifications / 4. Design and function
Process connection
In accordance with the general technical regulations for pressure
gauges (e.g. EN 837-2 "Selection and installation recommendations for
pressure gauges"), plastic, G 1/8 female threads
Operating temperature
Ambient: -30 ... +80 °C
Medium: -16 ... +50 °C
Temperature effect
When the temperature of the measuring system deviates from the
reference temperature (+20 °C): max. ±0.5 %/10 K of full scale value
Ingress protection
IP 54 per EN 60529 / lEC 529, optionally IP 65
EMC Directive
Per EN 61000-6-4 and EN 61000-6-2 (cable length max 30 m)
For further specifications see WIKA Data Sheet PM 07.40, PV 17.40
and the order documentation.

4. Design and function

Description
Nominal size 110 mm
The instruments measure the pressure by means of diaphragms
(silicone)
The measuring characteristics are in accordance with the EN 837-3
standard and ventilation and air conditioning (VAC) regulations
Scope of delivery
Cross-check scope of delivery with delivery note.
WIKA operating instructions air2guide models A2G-10, A2G-15