Switch
On
4
Pulse
20 ms
width
Switch settings – SW2 (continued)
Off
100 ms
Sets the SSR2 pulsed output width to either 20 ms or 100 ms. It
also sets the minimum pulse width of the SSR1 output to either
20 ms or 100 ms.
If the pulse width is set to 20 ms, the cycle time for the latch mode
functions is reduced and the spindle speed is five times faster. In
certain cycles, ensure the maximum rpm of the tool is not
exceeded.
NOTE: For the cycle to work, the pulse width value selected must
be the same as the value that is configured in the tool setting
software.