Herunterladen Inhalt Inhalt Diese Seite drucken

Switch Settings - Sw1 - Renishaw NCi-4 Installations- Und Benutzerhandbuch

Für berührungslose werkzeugkontrollsystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1-8
IMPORTANT: Setting a switch
When setting a switch to either the On or Off position,
apply firm pressure to make sure it is fully in position.
Switch bank SW1
1
Not used
On
2
NC set-up
On
3
Drip rejection
On
Switch settings – SW1
Off
Not used.
Off
Used when setting up an NC4 system. Set this switch to On so
that the alignment voltage can be maximised. After maximising the
voltage, set the switch to Off so that the automatic gain circuitry
can fine-tune the operating voltage.
When setting up the NC1 or NC3, set this switch to On for
5 seconds then set it to Off. This automatically configures the
NCi-4 interface to operate with the NC1 or NC3.
Off
When the drip rejection mode is set to On, the effects of individual
drops of coolant on measurements are filtered out.
NOTE: For safe operation, set the spindle speed and spindle
override as described below.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis